Electrical
Replacement Power Board
Disconnect the unit from the power
source before beginning service
work. Incorrect use or connections
can cause electrical shock.
Wear safety goggles when working
with refrigerants. Refrigerants can
cause eye injury.
Use extreme caution when discon-
necting hoses. Pressurized refriger-
ant may be present in hoses. Point
hoses away from you and anyone
nearby.
Instructions
These instructions outline the basic steps to
replace the power board. Follow the prompts
on the control panel to move through the pro-
cedure correctly.
Figure 3-5. Power Board Connector Identification
Remove the Existing Power Board
1. Disconnect unit from the power source.
2. Remove shroud.
3. Disconnect all wires from power board.
4. Remove screws securing power board in
place, and remove power board.
Install the Replacement Power Board
1. Install new power board, and secure in place
with screws.
2. Connect wires as shown in power board
wiring diagram. See Figure 3-5.