ACS 561 Service Manual
Robert Bosch GmbH
SP00D00517
2018-07-11
16
Diagnostics and Testing
UNIT SPECIFICATIONS
GENERAL INFORMATION
Voltage:
220 – 240VAC (230VAC Nominal)
Frequency:
50 – 60 Hz
Amperage:
6.0 Amps @ 230VAC
Refrigerant:
R1234yf (SAE J-2099)
Storage Temperature Range:
-20°C to 70°C (0°F to 140°F)
Operating Temperature Range:
10°C to 50°C (50°F to 120°F)
Normal Ambient Operating Conditions
Temperature:
21°C ± 9°C (70°F ± 15°F)
Relative Humidity:
86% Non-condensing at 32.2°C (90°F)
Altitude:
0 – 2000 m (0 – 6561 ft.)
Refrigerant Removal
Amount:
95% within 30 minutes
Temperature:
21°C (70°F)
Accuracy:
± 30 g (± 1 oz)
Vacuum Pull
Volume:
40 Microns
Refrigerant Recharge
Accuracy:
Full rated charge ± 15 g (± 0.50 oz)
Recycling Filter Type:
260 g
Unit Height:
127 cm
Unit Width:
69 cm
Unit Depth
66 cm
Shipping Weight:
80 kg
Certification:
UL1963
SAE J-2843, CE marked, and others
Compressor
Voltage:
187-253VAC (230VAC Nominal)
Frequency:
50 – 60 Hz
Amperage:
2.6 Amps @ 230VAC
Locked Rotor Amperage:
13.5 Amps
Capacity
926 Watts
Oil Charge
300 cm³
Displacement
8.85 cm³
Vacuum Pump
Voltage:
220 – 240VAC
Frequency:
50 – 60 Hz
Amperage:
3.0 Amps @ 230VAC
Locked Rotor Amperage:
1/4 HP
Oil Capacity
310 ml
Displacement (Free Air)
70l/min (2.5CFM)
Stages
1
Ultimate Vacuum
40 Microns
Summary of Contents for ACS 561
Page 1: ...ACS 561 en Repair instruction A C Service Unit ...
Page 95: ......