ACS 561 Service Manual
Robert Bosch GmbH
SP00D00517
2018-07-11
43
Diagnostics and Testing
ERROR/WARNING
PROCEDURE
DESCRIPTION OF ERROR/
WARNING
Air Flow Calibration failed!
Calibrate Air Flow
Air flow sensor is not reading air flow
correctly. Press
Retry
(
F1
) or
Exit
(
F2
).
Calibration failed! Offset is
negative
Calibrate Load Cells
Offset between the two weights is
negative. Press
Retry
(
F1
) or
Exit
(
F2
).
Calibration failed! Slope is out
of range.
Calibrate Load Cells
Difference between upper and lower
limits is too great. Press
Retry
(
F1
)
or
Exit
(
F2
).
Calibration failed! Verification
weight X. XXXYY.
Calibrate Load Cells
Weight too high or low.
Press
Retry
(
F1
) or
Exit
(
F2
).
Calibration failed.
Calibration Check
Press
Retry
(
F1
) to return to the
beginning of the calibration check,
or
Exit
(
F2
) to return to the service
menu.
Insufficient vacuum for
charge.
Charge
System vacuum to low to draw in
enough refrigerant. Press
Vacuum
(
F1
) or
Exit
(
F2
).
Insufficient refrigerant
available for charge.
Charge
Refrigerant in ISV too low. Press
Retry
(
F1
) or
Exit
(
F2
). May require
tank fill.
Leak test failed!
Charge Leak Test
Check for leaks and retest.
Press
Exit
(
F2
).
Oil drain halted. Pressure
error.
Drain Oil
Pressure insufficient to push oil out
of separator. Press
Retry
(
F1
) or
Exit
(
F2
).
Oil drain halted. Flow error.
Drain Oil
Oil drain timed out. Press
Retry
(
F1
)
or
Exit
(
F2
).
Invalid password!
Enter Password
Password entered is incorrect. Verify
function password is correct. Press
Retry
(
F1
) or
Exit
(
F2
).
Charge stalled! Check
connections and valves.
XX.XXXYY of XX.XXXYY
charged.
Fast Charge
Check panel valve position and
couplers. Press
Retry
(
F1
) or
Exit
(
F2
).
Invalid serial number!
Filter Change
Filter serial number must be different
from any other filter serial number
previously installed. Press
Re-Enter
(
F1
) or
Exit
(
F2
).
Summary of Contents for ACS 561