BEI JING BOREY TECH CO., LTD Website:www.en.boreytech.com
In fact basic point of first board in second array in basic point of end board in first
array;After saving basic point of end board in first array,please switch it to second
array and save it to basic point of first board in second array;The precondition is X
and Y not moved after saving first level array,it should be switch to moving table
directly.(Speed)
Basic point of end board in second array is same point which is in an X axis and
farthest unit with basic point of first board.Please see Figure 8.
Figure 8
Operator only move PCB moving table,then find basic point of end board by
camera,then OK to save.
Programming Tips
(
A
)
The operator should set the relationship between nozzle and shelf frame and relationship
in parameter settings to one-to-one correspondence in the programming,otherwise the
programming will be disordered.
(
B
)
Pay attention to when it comes to “first-level array”during programming,the operator
only allows to move the XY axis for positioning,PCB sliding table movement is not
allowed,then when involving “second-level array”when in programming,only allowed to
move the PCB sliding table,not allowed to move XY axis.
(
C
)
There are a lot of kinds of sketchpad software,so leading-in is not included in the scope of