41
■ Comparator weighing mode :
r1.
L
on, r2.
r
on, r3.
H
on
: Indicates the result of judgment and turns on.
If L1 judgment value
≦
L2 judgment value
≦
L3 judgment value.
L3 Hi, Lo value
L2 Lo value
L2 Hi value
L1 Hi, Lo value
[ HI ]
[ OK ]
[ LO ]
LO (L1) Relay Output
OK (L2) Relay Output
HI (L3) Relay Output
Weight
Time
OFF
0
L2 ON
L2 ON
L2 OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
L2 OFF
Example )
L1 – L ON
mode
rLY.1H
L1 Hi side judgment value
999
999 beyond the limits will activate a relay
ON
999 within the limits will activate a relay
OFF
rLY.1L
L1 Low side judgment value
999
L2 – Range
ON mode
rLY.2H
L2 Hi side judgment value
3000
3000 within the limits will activate a relay
OFF
1000 beyond the limits will activate a relay
OFF
In the range of relay
ON
rLY.2L
L2 Low side judgment value
1000
L3 – H ON
mode
rLY.3H
L3 Hi side judgment value
3001
3001 within the limits will activate a relay
ON
3001 beyond the limits will activate a relay
OFF
rLY.3L
L3 Low side judgment value
3001