29
M
High Precision DIGITAL INDICATOR
M
High Precision DIGITAL INDICATOR
M
High Precision DIGITAL INDICATOR
M
High Precision DIGITAL INDICATOR
Item Display
Setting Value
Contents of Setting
Number of
Communication Output
Number of communication output
shall be set.
0.01: 0.01 sec/time
~
9.99: 9.99 sec/time
Data is transmitted for each set
time interval.
Warning :
Transmission is not
conducted with the setting of 0.00
and there may be an overlapping
of transmission packet when
communication speed is set to be
slow in high speed transmission.
In case of setting transmission
speed is conducted as 9600bps or
lower, it shall be set as 0.1 sec or
longer.
Int
0.10
Stream mode
setting range
0.01 ~ 9.99
rECALL
Command mode
(transmission mode
upon data request)
Refer to communication format
(Page 50~57)
Communication format
bS235 BONG SHIN Format
Select communication format.
Warning : In case of AND Format or
BS-7300 setting, command mode is
same as the 11-2-2 command mode.
bS205 BONG SHIN Format
bS7300 BONG SHIN Format
And AND Format
Communication
RS-422/485 setting
Select RS-422/485 communication.
Warning 1 :
After changing from
RS-485 to RS-422, turn the power
off and then use is after turning it on.
Please use it after checking the
output pin no.
Warning 2 :
If the option is equipped
with RS-232C, you cannot select it in
the settings and only RS-232C is
displayed.
r S-422
RS-422
r S-485
RS-485
: Initial Value
Since entry to setting mode is unavailable from Key Lock status, it shall be executed after
canceling the key lock.
There may be a change in display of setting range based on location of decimal point.
Item to set DAC is not displayed when selecting serial communication option.
Item to set Serial communication is not displayed when selecting DAC option.
Function setting value can be initialized at check mode.