Via parameter
Operation mode
435, the drive is configured as a master drive or
slave drive.
Operation mode
435
Function
0 - Off
The traverse function is deactivated.
1 - Master Drive
Operation as master drive.
2 - Slave Drive
Operation as slave drive.
For traverse mode, the reference value source is selected via parameter
Reference
frequency
48.
Traverse mode becomes active as soon as the
Reference frequency
48 is reached for
the first time. This frequency is reached via the values for
Acceleration (clockwise)
420 and
Acceleration Anticlockwise
422 and
Deceleration (clockwise)
421 and
Deceleration anticlockwise
423. In shot-effect mode, the values for
Acceleration
Time
436 and
Deceleration Time
437 are active.
The frequency range for shot-effect mode is limited by the
Minimum frequency
418
and the
Maximum frequency
419.
During traverse operation, the configured traverse parameter values cannot be
changed.
The source of the handshake signal is selected via
Handshake Traverse Function
49.