Key functions
ENT
Reversal of the sense of rotation independent of the control signal on the
terminals Clockwise S2IND or Anticlockwise S3IND.
ESC
Cancel function and return to the menu structure.
FUN
Switch from internal set point int or motor potentiometer function Pot to
JOG frequency; the drive starts.
Release the key to switch to the sub-function and stop the drive.
RUN
Start drive; alternative to control signal S2IND or S3IND.
STOP
Stop drive; alternative to control signal S2IND or S3IND.
CAUTION
If you press the ENT key, the sense of rotation is changed independent of the
signal on the terminals Clockwise S2IND or Anticlockwise S3IND.
If the
minimum frequency
418 has been set to 0.00 Hz, the sense of rotation of
the motor changes as soon as the sign of the reference frequency value changes.
100
Operating Instructions ACU