14.4.10
Electronic Gear: Slave
The
Electronic Gear: Slave mode is selected via Object
= 0xFD = -3.
In
Electronic Gear: Slave mode the drive follows as Slave a Master drive.
Related objects:
Control word
Status word
Modes of operation
Velocity min max amount
Modes of operation display
Electronic Gear: Gear factor
…
Electronic Gear: Phasing 1
…
Electronic Gear: Phasing 4
M/S Synchronization offset
In “Electronic Gear: Slave mode” the "operation mode specific" and “manufacturer
specific” bits of
Control word and Status word are used as shown:
Control word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Switch on
1
Enable voltage
2
Quick stop (low active)
3
Enable operation
4
Start Gearing
5
Start M/S Correction
6
Direct Sync
7
Fault reset
8
Halt
9
Start Phasing
10
-
11
-
12
Phasing switch over 0
13
Phasing switch over 1
14
-
15
-
07/13
CM-EtherCAT