12.5.18
0x6068/0 Position window time
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x6068
0
Position window time
Unsigned16
rw
No 0xA
(=10)
Object works in:
•
o
All modes
Object doesn’t work in:
•
Non motion Control (conf.
≠
x40)
When the actual position is within the
position window during the defined position win-
dow time (given in milliseconds), then the corresponding bit in the Status word (bit 10
target reached) is set to one. This is considered in Modes that use Status Word Bit 10
“Target reached” as “Target Position reached” like “Profile Positioning Mode” and “Table
Travel Record Mode”.
Writing to object
position window time automatically generates a write command to
parameter
Target Window Time
1166 (data set 5, all data sets in RAM only !).
If object 0x6068/0 was written and then a save parameters command (object
processed, the object value is stored in non-volatile memory.
After the next power on of the inverter, the previously set value is reactivated and
overwrites the setting of
Target Window Time
1166.