Every 500 operating hours
BOMAG
71
BW 213 D-4
Checking the refrigerant level
l
Start the engine.
Fig. 97
l
Switch the air conditioning (Fig. 97) on.
Fig. 98
l
Choose a cooling temperature with the rotary
switch for cabin heater (Fig. 98) in the blue
section.
l
Open the air outlet nozzles.
l
Check, whether the outflowing air is noticeably
cooler.
i
Note
The adjusted temperature must be below the actu-
al temperature inside the cabin, so that the com-
pressor will be switched on.
l
Open the hood.
Fig. 99
l
Check whether the white float (Fig. 99) inside
the inspection glass of the drier/collector unit
floats right at the top.
i
Note
The refrigerant level is correct.
Fig. 100
l
If the white float (Fig. 100) inside the inspec-
tion glass of the drier/collector unit floats at the
bottom, inform the service department.
i
Note
The refrigerant level is not correct.
l
Refrigerant must be filled up, if necessary
check the air conditioning system for leaks.
Summary of Contents for BW 213 D-4
Page 2: ......
Page 7: ...BOMAG 7 BW 213 D 4 1 Technical Data...
Page 11: ...BOMAG 11 BW 213 D 4 2 Safety regulations...
Page 18: ...Safety regulations BOMAG 18 BW 213 D 4...
Page 19: ...BOMAG 19 BW 213 D 4 3 Indicators and Controls...
Page 20: ...Indicators and Controls BOMAG 20 BW 213 D 4 Fig 5...
Page 30: ...Indicators and Controls BOMAG 30 BW 213 D 4 Constant end of compaction...
Page 31: ...BOMAG 31 BW 213 D 4 4 Operation...
Page 46: ...Operation BOMAG 46 BW 213 D 4...
Page 47: ...BOMAG 47 BW 213 D 4 5 Maintenance...
Page 95: ...BOMAG 95 BW 213 D 4 6 Trouble shooting...
Page 99: ...Trouble shooting BOMAG 99 BW 213 D 4...
Page 100: ...Trouble shooting BOMAG 100 BW 213 D 4...
Page 101: ......
Page 102: ......