 Forced convection (with optional fans)

If the optional fans are installed, the fans draw the hot air from the air intake to the 

front of the appliance and to the hot air outlets. 
The use of ducts is not always essential in forced convection, but it does allow an 

improved distribution of heat throughout the home.
As a reminder, always make sure that the wood-burner is electrically powered before 

use. If there is a temporary power failure, reduce the flame to prevent the appliance 

and fans from overheating.

2.6. Fans (optional)

This wood-burner can be optionally equipped with two fans and an electronic control 

system. 
This system: 

•  automatically controls the fan speed based on 

the temperature of the wood-burner,

•  monitors the fans and detects faults or possible 

clogging.

The complete system consists of:

•  two fans and a circuit board mounted on the right 

cover.

• 

a speed selector, 

• 

a sealed power pack.

Both fans extract the air between the heater and the 

cladding to improve heat recovery. This increases the 

diffusion and distribution of heat in the room.
The circuit board can automatically vary the speed of 

the fans and control their operation.

Operation

As soon as the wood-burner begins to heat up, the 

fans start automatically at minimum speed. Then, the 

hotter the appliance, the faster the fans will turn.

Nucená konvekce (s volitelnými ventilátory)

Pokud volitelné příslušenství ventilace je nainstalováno, teplý vzduch je ventilátory 

u  vstupních  průduchů  vháněn  do  přední  strany  krbové  vložky  a  až  k  výdechům 

teplého vzduchu

.

U nuceného oběhu není nutná přítomnost rozvodů, ale ty umožňují lepší proudění 

teplého vzduchu do místnosti

.

Vždy se před použitím ujistěte, že je ventilátor připojen ke zdroji napájení. V případě 

poruchy dodávky proudu snižte plamen, abyste předešli přehřátí krbové vložky a 

ventilátorů.

2.6. 

v

entilace

 (

volitelné

 

vybavení

)

Tato krbová vložka může být vybavena dvěma ventilátory a elektronickým kontrol

-

ním systémem. 

Tento systém umožňuje:
• 

automatické ovládání rychlosti ventilátorů v závislosti na  

teplotě krbové vložky,
• 

kontrolu ventilátorů a detekci závad nebo případných zanese

-

ní.
Celý systém se skládá z:
• 

dvou ventilátorů a jedné elektronické karty, která je umístěna 

na pravé straně zakončovacího krytu vložky,
• 

voliče rychlosti, 

• 

hermeticky uzavřeného napájecího zdroje.

Oba ventilátory vhánějí vzduch mezi topné těleso a plášť, čímž na

-

pomáhají rekuperaci teplého vzduchu. To zlepšuje rozvod a distribuci 

tepla v místnosti.
Elektronická karta automaticky nastavuje různé rychlosti ventilátorů a 

kontroluje jejich správné fungování.

Provoz

Jakmile se krbová vložka začne zahřívat, automaticky se spustí ven

-

tilátory na nejnižší rychlost. Jakmile je vložka zahřátá, rychlost venti

-

látorů se zvýší.

Door switch

systém přerušení 

dvířek

speed selector

volič rychlosti

red led and test button

červená kontrolka a testo

-

vací tlačítko

Summary of Contents for Concept 540

Page 1: ...e been performed The installer must explain the appliance s operation to the user and provide them with this manual 07DHCON2ENCZ version 24 11 2017 Concept 540 Concept 540 DF Concept 540 V Concept 540...

Page 2: ...o address all the particularities of every special case of installation we have limited ourselves to the key points V en z kazn ku gratulujeme V m k zakoupen krbov vlo ky Bodart Gonay Jsme r di e jste...

Page 3: ...o shod 38 6 2 Identifikace a referen n slo modelu 38 6 3 Technick parametry 38 Table of Contents 1 Installation 4 1 1 Combustion air 4 1 2 Convection air 6 1 3 Decompression air 7 1 4 Chimney duct 8 1...

Page 4: ...mm maximum length of 10 m counting 1m per 90 elbow e g maximum 6m and 4 elbows It is advisable to use a duct with a smooth interior and to avoid spiral 1 Instalace Tato za zen jsou vyr b na v souladu...

Page 5: ...n type C or D presence of exhaust hood a specific air inlet must be provided or choose the installation of an outside air duct previous case Doporu ujeme pou t potrub uvnit hladk a vyh bat se flexibil...

Page 6: ...ys be electrically connected and in functional condition see fan section 1 2 Konvek n vzduch Konvek n vzduch je vzduch erpan z m stnosti a oh van krbovou vlo kou Vzduch se oh v kontaktem s vn j m povr...

Page 7: ...ilu 200 300 cm Hot air ducts In natural or forced convection the hot air ducts allow the heat that is produced to be transferred to an adjacent room They must be connected to the hot air outlets us in...

Page 8: ...ainwater dripping into the wood burner If these points can not be guaranteed plan the duct ing renovation or installation of a new chimney 1 4 Kou ovod Kou ovod je nutn sestavit dle p epis Pro zaji t...

Page 9: ...d then lowering the other side Next remove the side parts by positioning them diagonally Nedodr en t chto doporu en m e m t negativn d sledky slo it zat p n zp tn tah mal i p li velk tah po kozen krbo...

Page 10: ...n attach the bushing onto the box 3 Insert and position the fireplace in the niche at the correct height and level left Zadn d ly pro modely s jednoduch m opl t n m Jakmile jsou postrann d ly pry zadn...

Page 11: ...tall the appliance s cladding 12 Replace the frame the side covers and the door s Note The frame is attached using the 4 fixing screws The frame can be aligned with the cladding by an adjustment 15mm...

Page 12: ...hose used for the inset version previous chapters If you want to attach the wood burner and its cladding to the base remove the side covers and the door to access the floor fasteners 1 9 Pl Doporu uje...

Page 13: ...e circuit board requires to control the fans This power pack should always be installed so that it is accessible at Krbovou vlo ku postavte na v ez a spojte s podstavcem Posu te opl t n po krbov vlo c...

Page 14: ...re of the plate The fans can then be disconnected removed and or cleaned 3 Reassembly consists of replacing the components in reverse order fans with blower facing upwards Nikdy nap jec zdroj neumis u...

Page 15: ...ve not been installed To use this setting set the 4 switches to 0001 first 3 down fourth up Zapojen Kabel od ventil tor je prim rn instalov na ke v em krbov m vlo k m Jakmile jsou ventil tory na sv m...

Page 16: ...1600 rpm Never leave the board in test mode while the appliance is operating Jakmile je nastaven zm n no zapn te znovu kartu aby do lo k na ten nov ho typu nastaven Pro zapnut karty jsou mo n dva zp s...

Page 17: ...ujte jeho spr vn um st n 1 13 First fire The first fire is important as it bakes the paint allows for baffle adjustment provides the opportunity to check that the appliance functions correctly Ventila...

Page 18: ...s main com ponents 1 The door structure is located behind the window with the door posts inclined inwards This means that the door provides a clear view of the fire 2 The two position latch means that...

Page 19: ...ffle The baffle can also slow down the combustion gases allowing heat to be transferred back to the wood burner stove It is essential that the baffle is correctly adjusted for the appliance to functio...

Page 20: ...words the temperature at which the air valve closes Move the control by placing your finger on its edge and turning it to the right towards the to increase the Otev en a zav en dv ek Dv ka se otev raj...

Page 21: ...wards the to reduce the flame Using a glove is advisable when touching the control Using a glove is advisable when touching the control Safety Compliance with the operating instructions in this manual...

Page 22: ...tion of the stove The guarantee does not cover damage due to overheating the appliance Insufficient wood loading results in decreased efficiency excessive draw dirtying of the wood burner blackening o...

Page 23: ...8 When the fireplace is hot the fans optional start automati cally This may occur at the end of the lighting procedure or later on after the wood burner has been reloaded 2 4 Obsluha ohni t D le it z...

Page 24: ...of primary air setting too low To do this adjust the air supply until the fire is burning sufficiently Ve f zi zat p n kdy jsou dv ka otev en m e doch zet k m r n mu zp tn mu tahu Neotev rejte dv ka p...

Page 25: ...the air outlet in the wall Provoz p i ni rychlosti spalov n Pokud p ikl d me men mno stv palivov ho d v sni ujeme v kon krbov vlo ky a prodlu ujeme tak dobu mezi jednotliv mi f zemi p ikl d n p in te...

Page 26: ...ster the fans will turn Nucen konvekce s voliteln mi ventil tory Pokud voliteln p slu enstv ventilace je nainstalov no tepl vzduch je ventil tory u vstupn ch pr duch vh n n do p edn strany krbov vlo k...

Page 27: ...restarted after closing the door This is due to the fan s inertia and is not a defect Voli rychlosti p izp sobuje re imy ventil tor rychlost 0 VYP v tr ky se spust jen v p pad p eh t krbov vlo ky ryc...

Page 28: ...g the board Pressing the test button for 5 seconds will restart the circuit board Kontroln re im ventil tor Na elektronick kart pod syst mem p eru en dv ek je tla tko integrovan k er ven kontrolce Umo...

Page 29: ...necessary use a vacuum cleaner to unclog the air inlet holes of the stainless steel air dispatchers They can be removed to facilitate the operation 3 dr ba 3 1 B n dr ba Keramick sklo Pro i t n skla...

Page 30: ...s high temperature spray paint avail able from your distributor BG paint is the only range that will guarantee the same colour and chemical compat ibility with the original paint Dekompresn a konvek n...

Page 31: ...f this bracket so that the door switch clicks just before the door is completely closed At tention if this bracket is incorrectly adjusted and pushes too far it can break the switch or the circuit boa...

Page 32: ...delivered in exchange for defective parts The following charges are not covered by the guarantee transportation and packing costs damage or interest resulting from the non use of the appliance 4 Z ruk...

Page 33: ...he right to independently modify its appliances cata logues and user instructions at any time and without notice Doporu ujeme dodr ovat platn m stn i evropsk bezpe nostn p edpisy jak p i instalaci tak...

Page 34: ...ENT FUEL FOR LIGHTING INCREASE THE QUANTITY 9 FUEL USED FOR LIGHTING TOO DAMP CHANGE IT AND USE DRIER FUEL THE FIRE IS SMOUL DERING CHECK THE CAUSES 3 4 5 7 APPLY THE CORRESPONDING SOLUTION 10 EXCESSI...

Page 35: ...R REPLACEMENT BY THE INSTALLER THE FAN DOES NOT START 23 ELECTRICAL POWER SUPPLY CHECK THE ELECTRICAL SYSTEM FUSE CHECK THE VOLTAGE ON THE BOARD BY PRESSING THE TEST BUTTON PRESS AGAIN TO EXIT TEST MO...

Page 36: ...TATEK PALIVOV HO D V PRO Z TOP ZVY TE MNO STV 9 P LI VLHK PALIVOV D V PRO Z TOP VYM TE ZA SU PALIVO OHE UHAS N PROV TE BODY 3 4 5 7 APLIKUJTE ODPOV DAJ C ODSTRAN N P INY 10 P LI VLHK PALIVOV D V P IDE...

Page 37: ...CE NEFUNGUJE 23 NAP JEN OV TE ELEKTRICK VEDEN POJISTKY OV TE P TOMNOST NAP T U KARTY STISKEM TESTOVAC HO TLA TKA OP TOVN M STISKEM SE VR T TE DO TESTOVAC HO RE IMU V M NA NAP JEN 24 V TESTOVAC M RE IM...

Page 38: ...13229 Vestavn spot ebi e k vyt p n a krbov vlo ky na pevn paliva Po adavky a zku ebn metody SN EN 60335 1 Elektrick spot ebi e pro dom cnost a podobn ely SN EN 55014 1 a SN EN 55014 2 Elektromagnetick...

Page 39: ...u Ru n ovl d n dvou i v ce lo isek Bez kontroly teploty v m stnosti Za spole nost BG Fires Matthieu LEGRAND R D Manager Model Number of doors Door height H mm Door width W mm Rated performance kW Effi...

Page 40: ...Verkoper invoerder Nom Naam Adr CP PC Tel Pays Land Ville Plaats Fax Acheteur Aankoper Nom Naam Adr CP PC Tel Pays Land Ville Plaats Fax Etiquette code barre coller Barcode etiket hier plakken Signatu...

Reviews: