"WARNING" Message Display Function
The STP control unit is provided with a "WARNING" message to display when an
overhaul is needed following a self test.
When a "w" appears in the upper left hand corner of the LCD, press and hold the
"ENTER" switch to display the warning message. The warning message
indicates that an overhaul is necessary. Please contact Service office for an
overhaul. (The "ENTER" switch can also be used in Remote Mode.)
Example:
WARNING
First Damage Limit
w Levitation
"ENTER"
The upper line of the LCD displays the
operation status of the STP pump. The "w"
is displayed in each state (acceleration,
normal operation, and deceleration) of the
pump.
Warning message
◇
The "WARNING" message cannot be reset by the "RESET" switch.
Service office is in charge of resetting the "WARNING" message.
◇
The STP pump can operate even when the "WARNING" message is
displayed.
It is recommended to have the STP pump overhauled as soon as
possible.
T
ro
ub
le
sh
oo
tin
g
◇
The STP pump can operate even when the "WARNING" message is
displayed except when "Second Damage Limit" is displayed.
Overhaul the STP pump when "Warning" message is displayed.
11.4.1
First Damage Limit
The touch down bearing inside the STP pump will be worn out caused by impact
or air in rush from outside. Also, touch down at the power failure causes wear.
The STP control unit adds the damage point at each "Disturbance" and "Mains
Failure" error. "First Damage Limit" is displayed when the accumulation point
attains the prime setting value. "First Damage Limit" cannot be reset. It is
recommended to have the STP pump overhauled as soon as possible.