BLUEBOX Advant UHF
Page 48 of 102
If IOx is used as output, the load has to be connected between Output pin 2
(channel 1) or Output pin 4 (channel 2) and
–
PWR pin 3; max applicable current
is 500mA.
If IOx is used as input, a clean contact or PNP transistor has to be connected
bPWR pin 1 and Input pin 2 (channel 1) or Input pin 4 (channel 2);
max applicable current is 10mA.
When the I/O is used as input, do not use it also as output to avoid
conflicts!
(c) Power supply interface:
5-poles M12 A-coded male connector