Parameter
Description
Range
Default
extension after the crossing of the
gate.
Gate Time
Maximum gate crossing time. If =0 the ‘gate’
mode is disabled, otherwise it is the maximum
gate crossing time.
0 … 99
seconds
0 … 99
minutes
0
Debounce
Time
The inputs debounce time. If =0 a minimum
bounce time of 50ms is internally set.
0.00 … 0.99
seconds
0.0 … 9.9
seconds
0
Where the input mode range means
•
0: Disabled;
•
1: ON -> Activate antennas; OFF -> Deactivate antennas;
•
2: OFF -> Activate antennas; ON -> Deactivate antennas;
The input 1 and 2 modes combination allowed are
Input 1 Mode
Input 2 Mode
ON -> Activate antennas; OFF -> Deactivate
antennas
Disabled
OFF -> Activate antennas; ON -> Deactivate
antennas
Disabled
Disabled
ON -> Activate antennas; OFF -> Deactivate
antennas
Disabled
OFF -> Activate antenna 1 & 2; ON ->
Deactivate antenna 1 & 2
The input/output parameters are stored in configuration page nr. 0x05 and are
managed through the
‘Read Configuration Parameters’ and ‘Write Configuration
Parameters’ commands as described in protocol technical manuals where the
parameters 1…7 fields with default values are:
1
2
3
4
5
6
7
Input1
Mode
Input2
Mode
Extension
Time
Gate Time
Debounce
Time
0x00
0x00
0x01
0x00
0x00
0x00
0x00
0x00
0x00
Where:
Summary of Contents for IDTRONIC GEN2 ADVANT UHF
Page 22: ...BLUEBOX Advant UHF Page 22 of 102 Standard Single Tag 15ms 20ms...
Page 75: ...BLUEBOX Advant UHF Page 75 of 102 7 Mechanical Drawings 5221U 5221U S 5237U 5237U S...
Page 76: ...BLUEBOX Advant UHF Page 76 of 102 5231U 5222U 5222U S...
Page 77: ...BLUEBOX Advant UHF Page 77 of 102 5238U 5238U S 5232U...
Page 78: ...BLUEBOX Advant UHF Page 78 of 102 5223U 5223U S 5239U 5239U S...
Page 79: ...BLUEBOX Advant UHF Page 79 of 102 5233U 5222U MB S...
Page 80: ...BLUEBOX Advant UHF Page 80 of 102 5238U MB S 5232U MB Alle dimensions in mm...
Page 98: ...BLUEBOX Advant UHF Page 98 of 102 Module 64 Words Out 0x80 0xFF 40 EndModule...