BLUEBOX Advant UHF
Page 26 of 102
The general parame
ters are managed through the ‘Read General Parameters’
and ‘Write General Parameters’ commands as described in protocol technical
manuals where the parameters 1…7 fields with default values are:
1
2
3
4
5
6
7
Device
Address
Serial1
Serial2
0x00
0x00
Filter Time
Flags
0xFF
0x48
0x10
0x00
0x00
0x01
0x80
Where:
Parameter
Description
Device
Address
Device address of the reader (0x00 … 0xFF).
Serial1
RS232/RS485 communication settings.
•
High nibble: baud rate:
o
0x0: 1200 bps;
o
0x1: 2400 bps;
o
0x2: 4800 bps;
o
0x3: 9600 bps;
o
0x4: 19200 bps;
o
0x5: 38400 bps;
o
0x6: 57600 bps;
o
0x7: 115200 bps.
•
Low nibble: data bits:
o
0x7: 7 bits;
o
0x8: 8 bits.
Serial2
RS232/RS485 communication settings.
•
High nibble: stop bits:
o
0x1: 1 bits;
o
0x2: 2 bits.
•
Low nibble: parity:
o
0x0: None;
o
0x1: Even;
o
0x2: Odd.
Filter Time
Reading management filter time (0 setting is internally overwritten with 1 second):
•
Decimal 0 … 99 for time in seconds (0 … 99 seconds);
•
Decimal 100 … 199 for time in minutes (0 … 99 minutes).
Flags
Flags. Single bits are dedicated to disable (0 value) or enable (1 value) functions:
•
Bit 7: Automatic buzzer management;
•
Bit 6: Automatic output 1 management;
•
Bit 5: Reading antenna information in Data Request, Queue Request and
Inventory commands;
Summary of Contents for IDTRONIC GEN2 ADVANT UHF
Page 22: ...BLUEBOX Advant UHF Page 22 of 102 Standard Single Tag 15ms 20ms...
Page 75: ...BLUEBOX Advant UHF Page 75 of 102 7 Mechanical Drawings 5221U 5221U S 5237U 5237U S...
Page 76: ...BLUEBOX Advant UHF Page 76 of 102 5231U 5222U 5222U S...
Page 77: ...BLUEBOX Advant UHF Page 77 of 102 5238U 5238U S 5232U...
Page 78: ...BLUEBOX Advant UHF Page 78 of 102 5223U 5223U S 5239U 5239U S...
Page 79: ...BLUEBOX Advant UHF Page 79 of 102 5233U 5222U MB S...
Page 80: ...BLUEBOX Advant UHF Page 80 of 102 5238U MB S 5232U MB Alle dimensions in mm...
Page 98: ...BLUEBOX Advant UHF Page 98 of 102 Module 64 Words Out 0x80 0xFF 40 EndModule...