Internal RF Channel
ETSI EN 302208-1 RF Channel
5
8
6
9
7
10
8
11
9
12
10
13
According to ETSI EN 302208-1 only channels 4, 7, 10 and 13
(internal numerated as 1, 4, 7 and 10) could be used at high power!
Other RF channels are present only for test purposes and should
not be used in normal operation!
According to integrated antenna specifications only Europe (ETSI)
region could be set in readers with EU integrated antenna (items
522xU[-MB]-S).
Hereinafter the configurable EPC C1G2 (Class-1 Generation-2) parameters of the
BLUEBOX
.
Parameter
Description
Range
Default
Inventory Mode
How the reader does an inventory in
‘continuous’ mode.
Fast Multi Tag,
Fast Single
Tag, Standard
Multi Tag,
Standard
Single Tag
Standard
Multi Tag
Link Frequency
Link Frequency as defined in EPC Class 1
Generation 2 protocol.
40, 160, 256,
320, 640 kHz
160 kHz
Bit Coding
Bit coding as defined in EPC Class 1
Geneneration 2 protocol.
FM0, Miller 2,
Miller 4, Miller
8
Miller 2
Q Selection
Algorithm
The Q selection algorithm used for setting the
slot-counter parameter as defined in EPC Class
1 Generation 2 protocol.
Dynamic
Fixed
Dynamic
Q Value
The Q value used in fixed Q selection algorithm
or the starting Q value used in dynamic Q
selection algorithm as defined in EPC Class 1
Generation 2 protocol.
0 … 15
3
Summary of Contents for IDTRONIC GEN2 ADVANT UHF
Page 22: ...BLUEBOX Advant UHF Page 22 of 102 Standard Single Tag 15ms 20ms...
Page 75: ...BLUEBOX Advant UHF Page 75 of 102 7 Mechanical Drawings 5221U 5221U S 5237U 5237U S...
Page 76: ...BLUEBOX Advant UHF Page 76 of 102 5231U 5222U 5222U S...
Page 77: ...BLUEBOX Advant UHF Page 77 of 102 5238U 5238U S 5232U...
Page 78: ...BLUEBOX Advant UHF Page 78 of 102 5223U 5223U S 5239U 5239U S...
Page 79: ...BLUEBOX Advant UHF Page 79 of 102 5233U 5222U MB S...
Page 80: ...BLUEBOX Advant UHF Page 80 of 102 5238U MB S 5232U MB Alle dimensions in mm...
Page 98: ...BLUEBOX Advant UHF Page 98 of 102 Module 64 Words Out 0x80 0xFF 40 EndModule...