BLUEBOX Advant UHF
Page 42 of 102
Parameter
Description
Q
Minimum and maximum Q value to be used in dynamic Q selection algorithm:
•
High nibble: minimum Q value (0x0 … 0xF);
•
Low nibble: maximum Q value (0x0 … 0xF).
Q Adjust
Rounds
Maximum Q adjust rounds in dynamic Q selection algorithm.
Inventory
Cycles
The inventory cycles in inventory command.
The changed ReadAfterDetect parameters become effective only
after a reset of the
BLUEBOX
. Reset the
BLUEBOX
using the
‘Reset Device’ command or via a hardware reset.
3.2.5
Dynamic Power Management
Hereinafter the configurable dynamic power management parameters of the
BLUEBOX
.
Parametro
Descrizione
Range
Default
Mode
How the reader manages the power in
‘continuous’ mode.
Off, Up,
Up/down
Off
Power Step
The
power
step
in
dynamic
power
management mode activated.
1 … 5 dB
10 … 500 mW
1 dB
Time Step
The time step in dynamic power management
mode activated.
0.1 … 9.9
seconds
1.0 sec
The dynamic power management parameters are stored in configuration page
nr. 0x07 and are managed through t
he ‘Read Configuration Parameters’ and
‘Write Configuration Parameters’ commands as described in protocol technical
manuals where the parameters 1…7 fields with default values are:
1
2
3
4
5
6
7
Mode
Power Step
Time Step
0x00
0x00
0x00
0x00
0x00
0x01
0x0A
0x00
0x00
0x00
0x00
Where:
Summary of Contents for IDTRONIC GEN2 ADVANT UHF
Page 22: ...BLUEBOX Advant UHF Page 22 of 102 Standard Single Tag 15ms 20ms...
Page 75: ...BLUEBOX Advant UHF Page 75 of 102 7 Mechanical Drawings 5221U 5221U S 5237U 5237U S...
Page 76: ...BLUEBOX Advant UHF Page 76 of 102 5231U 5222U 5222U S...
Page 77: ...BLUEBOX Advant UHF Page 77 of 102 5238U 5238U S 5232U...
Page 78: ...BLUEBOX Advant UHF Page 78 of 102 5223U 5223U S 5239U 5239U S...
Page 79: ...BLUEBOX Advant UHF Page 79 of 102 5233U 5222U MB S...
Page 80: ...BLUEBOX Advant UHF Page 80 of 102 5238U MB S 5232U MB Alle dimensions in mm...
Page 98: ...BLUEBOX Advant UHF Page 98 of 102 Module 64 Words Out 0x80 0xFF 40 EndModule...