6
Service Procedures
18
Revision 1/
© Moffat Ltd, January 2007
Blue Seal Evolution Series Gas Chargrills
6.2.9 Gas control valve
1) Remove control panel (refer 6.1.1).
2) Undo pilot supply, main supply and
disconnect pilot thermocouple from gas
control.
3) Undo compression nut securing gas control to
the manifold assembly.
4) Remove the gas control.
5) On suitable work surface, remove rear nut
from gas control.
6) Extract gas magnet.
7) Replace and reassemble in reverse order.
Figure 6.2.9
Gas Control
Magnet
Rear Nut
6.2.10 Gas control magnet
1) Remove control panel (refer 6.1.1).
2) Undo pilot supply, main supply and
disconnect pilot thermocouple from gas
control.
3) Undo compression nut securing gas control
to the manifold assembly.
4) Replace gas control and re-assemble in
reverse order.
Note: Ensure that the correct size injector is
refitted to gas control (refer specifications
section).
5) Adjust low fire setting (refer 6.3.2).
Manifold connection
Main burner
gas supply
Pilot supply
Thermocouple
Figure 6.2.10