Turn on oven. Oven should light normally and operate normally if new regular spring and spring retaining cap
were installed properly. Screw retaining cap down clockwise to increase pressure to manifold, turn
counterclockwise to reduce pressure. When manifold is 11” W.C. as shown, flames and combustion will be
optimized and you will see a good blue flame.
Turn off oven. Remove oven from gas supply.
Remove gas gage from burner manifold and replace with original brass pipe plug.
On the control valve, replace the top cap with the new red cap supplied and apply the sticker (supplied) to the
regulator that states it has been converted to LP gas operation.
Replace side cover.
Replace bottom burner cover.
Swing control panel back into normal position. Tighten retaining screw by hand on top of control panel to lock it
into place.
End of conversion procedure.