Step 4: Connect Electricity
!
WARNING
ELECTRIC GROUNDING INSTRUCTIONS
Thisappliance(120Vovensonly)isequipped withathree-prong(grounding)plugforyourprotection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
NOTICE
Thisappliance,wheninstalled,mustbe electrically groundedinaccordance withlocal codes,orinthe
absence of local codes, with the
National Electrical Code, ANSI/NFPA 70
or the
Canadian Electrical
Code, CSA C22.2
, as applicable.
Wiringdiagramsarelocatedonthesideofthecontrol panelassembly,aswellasinthismanual(beginning onpage 21).
Besurethat theinputvoltageandphasematchthe requirementsshownontheserial plate, which is located inside
thelower front panel.
Ovensorderedtooperateon
120V
powerhaveathree-wirecord.Single-ovenunitsrequirea15amperesupply.
Step 5: Connect Gas Supply
NOTICE
Theinstallationmustconformwithlocalcodes,orintheabsenceoflocalcodes,withthe
National
FuelGasCode,ANSIZ223.1,Natural GasInstallationCode,CAN/CGA-B149.1,
orthe
Propane InstallationCode
CAN/CGA-B149.2,
asapplicable, including:
1. Theapplianceanditsindividualshutoffvalvemustbedisconnectedfromthegassupplypiping
systemduringanypressuretestingofthatsystemattestpressuresinexcessof1/2psi(3.45 kPa).
2. Theappliancemustbeisolatedfrom thegas supplypiping system byclosingitsindividual manual
shutoffvalveduringanypressuretestingofthegassupplypipingsystemattestpressuresequal to or less than
1/2 psi (3.45 kPa).
A 3/4" NPT line is provided atthe rear for the gas connection.
Ifthisequipmentisbeinginstalledatover2,000feetaltitudeandthatinformationwasnotspecified when ordered,
contact the appropriate authorized Service Representative or the Service
Department.Failuretoinstallwithproperorificesizingwillresult inpoorperformanceandmayvoidthe warranty.
The serial plateislocatedinsidethefrontlowerpanel.Itindicatesthetypeofgastheunit is equipped to burn. All
equipment is adjusted at the factory. Check type of gas on serial plate.
Thesemodelsaredesign-certified foroperationon naturalorpropanegases.Fornatural gas,theregulator is set to
deliver a 3.5" W.C. pressure to the manifold.For propanegas, it is set to deliver 11"W.C.
ThisapplianceshouldbeconnectedONLYtothetypeofgasforwhichitisequipped.The inletpressure before
theregulatorshould be 6-10" W.C. for natural gas or 11-14"W.C. for LP gas.