19
A
DJUSTMENTS
!
WARNING
ADJUSTMENTSANDSERVICEWORKMAY BEPERFORMED ONLYBYA QUALIFIED TECHNICIAN
WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF
COMMERCIALCOOKINGEQUIPMENT.HOWEVER,TOASSURE YOUR CONFIDENCE, CONTACT
YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE
OROTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
NOTICE
Warrantywillbevoidandthemanufacturerisrelievedofallliabilityifserviceworkisperformedby other than
aqualified technician, or if other than genuine replacement parts are installed.
LUBRICATION
Motor lubrication information can be found on permanent label located on motor. Casters are providedwith
a Zerk fittingfor proper lubricationwhen required.
ADJUSTING GAS PRESSURE REGULATOR
Thepressureregulatorisfactorysetat3.5"W.C.fornaturalgasand11"W.C.forpropanegas.Tocheck the
manifoldpressure:
1. Turn all thermostats andburner valvesto “OFF” position.
2. Turn main gas valve to entire unit off.
3. Remove valve panels and locate 1/8" plug in manifold.
4. Remove plugand install afitting appropriate to connect a manometer.
5. Turn on maingas to unit and light pilots.
6. Turn all burners and ovens to full “ON” position and read manometer.
7. Ifmanometerdoesnotread3.5"W.C.fornaturalgas,or11"W.C.forpropanegas,adjustregulator(if gas pressure is
O.K. go to Step 10).
8. Removecapfrom top of regulator.
9. Withascrewdriverrotateregulatoradjustmentscrewclockwisetoincrease,orcounterclockwiseto decrease,
pressure until manometer showscorrect reading.
10.Repeat steps 1 and .
11.Remove manometer fitting and replace plug in manifold.
12.Repeat step.
13.Replace valve anels.