22
Blue Coat SG200 Series
If you have set flow control to
none
, and if you have
smooth-scroll
as an option in your terminal settings,
disable smooth-scroll in your terminal settings to reduce the chance of losing output.
2
Power on the SG200 and wait for the system to finish booting.
The following configuration alert displays:
Figure 2-8: Initial Setup—Configuration Alert
3
Press <Enter> three times.
When the
Welcome to the ProxySG Appliance Setup Console
prompt appears, the system is
ready for the first-time network configuration.
4
On page 1, press <Enter> to enter the bridge name
passthru-0
and enter the IP address, IP subnet
mask, IP gateway, and DNS server parameters.
•
Emulation: VT 100
Note:
If you have removed the pass-through card, you are asked if you want to configure a
software bridge. If you enter
YES
, you must configure at least one bridge port and
associate a network interface with it.
****************** CONFIGURATION ALERT ******************
System startup cannot continue for one of these reasons:
(a) Need at least one adapter (or bridge) configured with an IP
address and
subnet.
(b) Need the console password and enable password.
********* SYSTEM STARTUP TEMPORARILY SUSPENDED *********
Press "enter" three times to activate the serial console