INSTALLATION (continued)
5
NOTE:
This equipment must be
installed to comply with all
applicable plumbing codes and
ordinances.
WARNING ELECTRIC
SHOCK HAZARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT:
Do not connect
brewer to electrical power until
you are ready to fill the tank.
See instructions at left.
IMPORTANT:
This brewer
requires a dedicated 20 amp
single phase 220 to 240 volt AC
circuit. Contact a licensed
electrician to install the proper
circuit.
NSF requires that the brewer be able to be moved for cleaning
underneath. Loops of copper tubing will satisfy this requirement.
See Figure 2 below.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT:
Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Model 8783UK requires a dedicated 220 to 240 volt 20 amp
circuit (L1, L2) plus ground.
Model 8783UK is equipped with a cord with pin-type plug
(ME332P6-1311) and requires a matching receptacle.
See Figure 3 below.
Fig. 3 ME330P6-Series Plug
Fig. 2 Water Supply Installation