background image

PRECAUTIONS AND GENERAL INFORMATION 

WARNING:

  Electric Shock Hazard 

All servicing requiring access to non-insulated components must be performed by qualified 
service personnel.  Do not open any access panels which require the use of tools.  Failure to 
heed this warning can result in electrical shock. 

 

WARNING:

  Injury Hazard 

All installation procedures must be performed by qualified personnel with full knowledge of all 
applicable electrical and plumbing codes.  Failure could result in property damage and 
personal injury. 
 

WARNING Electric Shock Hazard 

Brewer must be properly grounded to prevent possible shock hazard.  DO NOT assume a 
plumbing line will provide such a ground.  Electrical shock will cause death or serious Injury. 

 

WARNING:

  Burn Hazard 

This appliance dispenses very hot liquid.  Serious bodily injury from scalding can occur from 
contact with dispensed liquids. 

This appliance is intended for commercial use only. 

 

This appliance is intended for use to brew beverage products for 
human consumption.  No other use is recommended or  
authorized by the manufacturer or its agents. 

 

This appliance is intended for use in commercial establishments, 
where all operators are familiar with the appliance use,  
limitations and associated hazards.  Operating instructions and 
warnings must be read and understood by all operators and  
users. 

 

Except as noted, this piece of equipment is made in the USA 
and has American sizes on hardware.  All metric conversions 
are approximate and can vary in size. 

 

The following trouble shooting, component views and parts lists 
are included for general reference, and are intended for use by 
qualified service personnel. 

 
This manual should be considered a permanent part of this 
appliance.  The manual must remain with the appliance if it is 
sold or moved to another location. 
 
 
 
Export versions of this brewer meet          requirements.  
 
This brewer meets 

      

 Standard 4 only when installed,        

operated and maintained in accordance with the enclosed        
instructions. 

CAUTION:

  

Equipment 

Electrical Damage 

 

DO NOT plug in or energize this 
appliance until all 

Installation     

Instructions 

are read and followed.  

Damage to the Brewer will occur if 
these instructions are not followed. 

 

CAUTION:   
Burn Hazard  
 

Exposed surfaces of the            
appliance, brew chamber and  
decanter or thermal server may be 
HOT to the touch, and can cause 
serious burns. 

STD 4

AGENCY LISTING INFORMATION 

Summary of Contents for 8783UK

Page 1: ...110702 cps 914 OWNERS MANUAL for AIRPOT COFFEE BREWERS WITH INDEPENDENT HOT WATER DRAW FAUCET MODEL 8783UK Includes Installation Operation Use Care Servicing Instructions Model 8783UK Brewer with opti...

Page 2: ...coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHAN...

Page 3: ...ins the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECI...

Page 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 Features Operating Controls...

Page 5: ...ents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must...

Page 6: ...een 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid d...

Page 7: ...TANT This brewer requires a dedicated 20 amp single phase 220 to 240 volt AC circuit Contact a licensed electrician to install the proper circuit NSF requires that the brewer be able to be moved for c...

Page 8: ...amber Be sure heater switches are OFF 2 Turn main power switch ON 3 Press BREW button and allow brew cycle to complete Repeat until water flows from the brew head 4 Place an empty container under the...

Page 9: ...button energizes the solenoid valve allowing water from an external water supply to flow into the basin pan and then into the hot water tank This forces an identical amount of hot water out of the tan...

Page 10: ...mber to level the bed of grounds Slide the brew chamber into place under the brew head B AUTOMATIC OPERATION BE sure READY COFFEE SYSTEM light is lit Place the appropriate EMPTY airpot or decanter in...

Page 11: ...disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent Rinse with clean water and allow to air dry 8 Wipe the exterior of the brewer with a...

Page 12: ...imit safety switch tripped Damaged internal component or wiring Timer out of adjustment Too many filter papers or wrong filter paper Brew chamber dispense hole plugged Too much coffee or too fine a gr...

Page 13: ...NT PANEL Remove front panel to access to terminal block brew timer and faucet water level controller Front panel is held by two retaining clips under main warmer cover plate and a retaining lip at the...

Page 14: ...ture adjustments may be made by removing the appropriate button plug from the side of the brewer then turning the thermostat adjustment shaft Check water temperature at the brew head for coffee or at...

Page 15: ...ter delivered Replace button plug REMOVE TANK LID ASSEMBLY Disconnect brewer from electric power Turn OFF water supply Remove top panel Disconnect fill and outlet tubes from tank lid fittings Disconne...

Page 16: ...r inlet fitting 2 Remove the tank lid assembly as described on page 13 3 Remove the coffee water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into t...

Page 17: ...Drain all water from the tank Using a stiff bristle brush scrub the interior of the water tank to remove lime and calcium build up Rinse with clean water drain then replace drain cap 7 Reassemble the...

Page 18: ...EXPLODED VIEW PARTS LIST 16 8783UK...

Page 19: ...EXPLODED VIEW PARTS LIST continued 17...

Page 20: ...SERVICE KITS 18 SERVICE KITS SOLENOID REPAIR KITS 86107 SOLENOID COMPLETE DUAL 0 75GPM 240V 85218 KIT INLET CAP INLET FITTING WASHER and SCREEN 85219 SCREEN ONLY...

Page 21: ...WIRING DIAGRAM 19...

Page 22: ...Bloomfield Industries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 698 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only...