Technical Manual
5-12
Main Menu
To reach the Main Menu, press
the ‘INFO’ button on the
instrument front panel. Note that
the ‘INFO’ button is only
functional from the weight display.
Navigating in a menu is done with
arrow keys or by clicking on the
desired line if a Web Browser is
used.
The instrument Main Menu is opened without interrupting the weighing.
In the Main Menu it is possible to select between the following sub menus:
Levels:
Viewing and editing of level value for each configured Level Supervision
function. Note that configuration of Level Supervision functionality is done in the
‘Parameter Set-up’ menu.
Setpoints:
Viewing of configured setpoint values. Editing of setpoint value is not
possible. Note that configuration of setpoint functionality is done in the ‘Parameter Set-
up’ menu.
Preset Tare:
Viewing and editing of preset tare value for the scale with tare correction
mode set to Preset or Auto + Preset. Set-up of Scale ‘Tare Corr. Mode’ parameter is
done in the ‘Parameter Set-up’ menu.
Accumulated Weights:
This menu shows the accumulated weights for the configured
scale. Accumulation of displayed weight (net or gross) takes place when a print
command is given either from front panel or via communication. Note that the displayed
weight is accumulated.
In the Accumulated Weights menu there is a possibility to zero all values by using the
soft key F2 (Zero) or via communication.
Accumulated weight is displayed if ‘Acc. Weight’ is selected in ‘Info. Lline 1/2 Mode’
parameter.
If in some of ‘Print Position 1 to 8’, ‘Acc. Weight’ is selected then the accumulated
weight will be printed at Print command. ‘Acc. Weight’ figures fills one position so to get
a header put in a ‘Acc. Label’ in the position to the left of ‘Acc. Weight’.
If ‘Long-term Data Store’ is ‘On’ then accumulated weight will be stored in the ‘Long-
term Data Store’ at Print command.
The instrument is capable of storing accumulated weight values up to 10 000 000 000
units with 3 decimals. When the limit is passed 10 000 000 000 will be subtracted from
the value.
Clock Set-up:
Used to set the instrument clock and date. Time and Date formats are
set-up with parameters trough ‘Parameter set-up’ menu.
Parameter Set-up:
Access to the G5 instrument parameter set-up menu system. See
chapter ‘Set-up’ for more details on setup.
Main Menu 10/08/2016 01:28 PM
9nter 9scape
Levels
Setpoints
Preset Tare
Accumulated Weights
Batched Weights
Clock Set-up
System Information
Maintenance
Network Configuration
Legal Weighing
Parameter Set-up
Main menu.