Charge on.
BlinkCharging.com
Page 44 of 56
With three connected vehicles, the charging currents are further reduced to 24A for 32A charging
stations and the charging current is 12A for 16A charging station.
Figure 35. Example 2 – Three Connected Vehicles
Example 3
In this example, there are five (32A) charging stations in the LLM group and two of the charging stations
are offline. Setting up each charging station according to the following settings:
Setting
Gateway
Client
Local Load Management
Enable
Enable
Charging Policy
Uniform Distribution
Not used
Group ID
LLM-Group-1
LLM-Group-1
(Same as Gateway)
Group Size
5
Not used
Max Amperage Grid
Connection
80
Not used
Fallback Current
10
10
(Same as Gateway)
Table 16. Example 3 – LLM Settings