Charge on.
BlinkCharging.com
Page 37 of 56
Charging Policy – The charging policy for LLM Gateway to decide the charging current for each EVSE.
Valid options are:
UD
(default): Uniform Distribution. The maximum amperage is divided by total numbers of charging
EV, i.e. each EV will use the same charging current.
FIFS
: First in First Serve.
Group ID
– An identity of the LLM group. A slave with different group identity will be rejected when
attempting to connect to Gateway.
Group Size
– The total number of EVSEs in the LLM group. This value is only used in Gateway.
Max Amperage Grid Connection
– Total ampere of each phase allowed loading for the group of
EVSEs at the same time. This value is only used in Gateway.
Fallback Current
– The fallback current when Client is not able to communicate with Gateway.
Gateway will overwrite fallback current in Client with its own value when Client connected to Gateway.
Note
Any option followed by a star mark (*) means the setting need to reboot to take effect. When these values are
changed and applied the web portal will display a reminder message box for rebooting the EVSE.