Figure 19. Configuration - OCPP 1.6 Settings (continued)
•
NumberOfConnectors
– The number of physical charging connectors of this EVSE.
•
ResetRetries
– Number of times to retry an unsuccessful reset of the EVSE.
•
ConnectorPhaseRotation
– The phase rotation per connector in respect to the connector’s
energy meter. Possible values per connector are:
•
NotApplicable (for single phase)
•
Unknown (not (yet) known)
•
RST (Standard Reference Phasing)
•
RTS (Reversed Reference Phasing)
•
SRT (Reversed 240 degree rotation)
•
STR (Standard 120 degree rotation)
•
TRS (Standard 240 degree rotation)
•
TSR (Reversed 120 degree rotation)
•
ConnectorPhaseRotationMaxLength
– Maximum number of items in a
ConnectorPhaseRotation configuration key.
•
StopTransactionOnEVSideDisconnect
– When set to true, the EVSE SHALL administratively
stop the transaction when the cable is unplugged from the EV.
•
StopTransactionOnInvalidId
– Whether the EVSE will stop an ongoing transaction when it
receives a non-accepted authorization status in a StartTransaction.conf for this transaction.
•
StopTxnAlignedData
– Clock-aligned periodic measurand(s) to be included in the
TransactionData element of StopTransaction.req MeterValues.req PDU for every
ClockAlignedDataInterval of the charging session. Supported value are Current.Import,
Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value.