SECTION 5: SPECIFICATIONS
Area
Parameter
Specification
Pan and Tilt (cont.)
Pattern
4 patterns, with a total recording time not less than 10 minutes
Power-off memory
Support
Park action
Preset / Patrol / Pattern / Pan Scan / Tilt Scan / Random Scan / Frame scan / Panorama scan
PTZ position display
On / Off
Freeze Frame
Support
Password protection
Support
Zone scanning / display
Scanning within programmed zone, display zone title
Camera Title
Programmable title display
Compass
Support, north direction can be set
Scheduled Task
Preset / Patrol / Pattern / Pan Scan / Tilt Scan / Random Scan / Frame Scan / Panorama Scan
RS-485 communication
diagnosis
Including failure information, such as wrong address, baud rate errors. Displayed on the video screen
in text
Manchester Code com-
munication diagnosis
Including failure information, such as wrong address, baud rate errors. Displayed on the video screen
in special characters
Alarms
Alarm input
2
Alarm output
1 relay output, alarm response actions configurable
Alarm action
Preset / Patrol / Pattern / Pan Scan / Tilt Scan / Random Scan / Frame Scan / Panorama Scan / Relay
Output
Input / Output
Monitor output
1.0 Vp-p / 75 Ω, NTSC composite, BNC
General
Menu Language
English, Chinese
RS-485 protocols
HIKVision, Pelco-P, Pelco-D, Self-adaptive
Power
24 Vac (-A model) maximum 18 W
Working Temperature /
Humidity
-22 °F ~ -149 °F (-30 °C ~ -65 °C) (outdoor dome) /
14 °F ~ 122 °F (-10 °C ~ 50 °C) (indoor dome ) 90% or less
Protection Level
IP66 standard (outdoor dome) TVS 4,000 V lightning protection, surge protection
Mounting
Various mounting modes optional
Dimension
Φ7.08” × 9.43” (Φ180 × 239.5 mm) (outdoor)
Φ6.50”×6.79 (Φ165×172.5 mm") (indoor)
Φ6.50” × 6.57” (Φ165×167 mm) (in-ceiling)
Weight (approx.)
4.41 Ib (2 Kg) (outdoor) 2 Kg (4.41 Ib) (indoor/in-ceiling)
Mounting options
Ceiling Mount Bracket: BLK-PTZCL;
Short Arm Wall Bracket 4” PTZ: BLK-PTZWBS;
Wall Mount: BLK-PTZWB;
Pole Mount PTZ Bracket: BLK-PTZPM;
Corner Mount PTZ Bracket: BLK-PTZCM;