Figure 4-173. LLDP parameter.
Parameter:
Tx Interval: Changes the interval between consecutive transmissions of LLDP advertisements on any given port. (Default: 30 seconds)
Tx Hold: Specifies the amount of time the receiving device holds a Link Layer Discovery Protocol (LLDP) packet before discarding it.
(Default: 4 times)
Tx Delay: Specifies the delay between successive LLDP frame transmissions initiated by value/status changes in the LLDP local
system’s MIB. (Default: 2 seconds)
Tx Reinit: Specifies the minimum time an LLDP port waits before reinitializing LLDP transmission. (Default: 2 seconds
)
Notification Interval: A network management application can periodically check the switch MIB to detect any missed change
notification traps. Refer to IEEE 802.1AB-2005 or later for more information. (Default: 5 seconds)
Mode: Enables or disables the LLDP mode per port. There are four types, including Disable, Tx_Rx, Tx only, and Rx only.
Port Descr: Enables or disables the outbound LLDP advertisements. This includes an alphanumeric string describing the port.
Sys Name: Enables or disables the outbound LLDP advertisements. This includes the system’s assigned name
Sys Descr: Enables or disables outbound LLDP advertisements. This includes an alphanumeric string describing the full name and
version identification for the system’s hardware type, software version, and networking application.
Sys Capa: Enables or disables outbound advertisements. This includes a bitmask of system capabilities (device functions) that are
supported. Also includes information on whether the capabilities are enabled.
Mgmt Addr: Enables or disables outbound advertisements, including information about the management address. Use this to include a
specific IP address in the outbound LLDP advertisements for specific ports.
Notification: Enables or disables outbound advertisements, including information on Notification.