Page 54
For configuration details, refer to
Chapter 6.6—Using SDT Connector to Telnet or SSH connect to devices
that are serially attached to the console server
.
4.1.4 Device (RPC, UPS, EMD) Mode
This mode configures the selected serial port to communicate with a serial controlled Uninterruptable
Power Supply (UPS), Remote Power Controller/Power Distribution Unit (RPC) or Environmental
Monitoring Device (EMD).
Select the desired
Device Type
(UPS, RPC or EMD)
Proceed to the appropriate device configuration page (
Serial & Network: UPS Connections, RPC
Connection
or
Environmental
) as detailed in
Chapter 8—Power & Environmental Management.
4.1.5 Terminal Server Mode
Select
Terminal Server Mode
and the
Terminal Type
(vt220, vt102, vt100, Linux, or ANSI) to
enable a
getty
on the selected serial port.
The
getty
will then configure the port and wait for a connection to be made. An active connection on a
serial device is usually indicated by the Data Carrier Detect (DCD) pin on the serial device being raised.
When a connection is detected, the
getty
program issues a login: prompt, and then invokes the login
program to handle the actual system login.
Note
Selecting Terminal Server mode will disable Port Manager for that serial port, so data is no longer
logged for alerts, etc.