CHAPTER 3: INSTALLATION
29
components beginning at the bottom of the rack, then work to the top. Do not exceed your rack load
rating.
CAUTION:
Power Considerations
-
Connect only to the power source specified on the unit. When multiple electrical components are installed
in a rack, ensure that the total component power ratings do not exceed circuit capabilities. Overloaded
power sources and extension cords present fire and shock hazards.
To install the rack mounting bracket:
1.
Remove the two rack mounting screws from each side of the Octet switch.
2.
Place the rack mounting brackets next to the switch as illustrated in Figure 3-4.
3.
Insert the screws supplied with the rack mounting kit through the holes of the brack-
ets and into the Octet switch. Tighten the screws securely.
Install the Octet switch into the rack using the approved method of the rack manufacturer.
Figure 3-4. Octet
Switch Rack Mounting Diagram
3.4
I
nstalling an Octet Switch
To install a new Octet switch, you will connect power sources, configure network settings
and connect the switch to the local area network (LAN).
NOTE:
Turn off the Octet switch and disconnect the power cord from the AC outlet before servicing.
Figure 3-5. Example of an Octet Switch Back Panel (KV1700A/E Switch Shown)
CAUTION:
To reduce the risk of electric shock or damage to your equipment
-
- Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
- Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times.
Network
Port
User
Ports
Server Ports
Summary of Contents for KV1700A/E
Page 2: ......
Page 8: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 6...
Page 20: ...SERVSWITCH OCTET INSTALLER USER GUIDE 18...
Page 50: ...SERVSWITCH OCTET INSTALLER USER GUIDE 48...
Page 86: ...SERVSWITCH OCTET INSTALLER USER GUIDE 84...
Page 96: ...SERVSWITCH OCTET INSTALLER USER GUIDE 94...
Page 107: ...NOTES 105...
Page 108: ...NOTES 106...
Page 109: ......