The battery charger is equipped with safety devices to ensure the utmost safety during
use and operation.
Full protection against sparks
Protection against short-circuits
Voltage compensation
Protection against overheating
Protection against polarity reversal
High protection rating against external agents, IP65
2.6.
Battery tests and error indications
The battery charger is designed to determine the battery’s condition before and while
charging, and inform about any connection faults between the battery charger and the
battery to charge.
LED / Icon /Error CAUSE
SOLUTION
Blink
Very low battery.
Charger is trying to recover the
battery.
The clamps/rings of the output
lead are not connected correctly
to the battery. Polarity reversal.
Position the clamps/rings
correctly and start charging the
battery again.
Blink
Battery voltage too high.
You are attempting to charge
a 24V battery with the
charger settled at 12V or you
are attempting to charge a
12V battery with the charger
settled at 6V.
Check the battery voltage.
Battery capacity excessive.
Use battery charger with greater
charging capacity.
Battery cannot maintain a good
level of charge.
The battery may be defective.
Contact your battery service
center.
Battery flat.
Press the button again, to restart
charging, and try to recover the
battery.
The battery may be defective.
Contact your battery service
center.
Battery unrecoverable after a
complete desulfurization cycle.
The battery may be defective.
Contact your battery service
center.