Gas Auto-Lift Fryer
Maintenance
40
11. The display will count up the time the pump is on to indicate the duration of the polishing. When done press
the
Off
button to stop the pump and press the right arrow button.
12. To refill the pot close the pot drain and make sure the fill handle is THRU POT.
Hot shortening may splash out of the pot causing severe injury when filling the pot.
13. Press the
On
button to start the pump and refill the pot.
Summary of Contents for BLG-TC Series
Page 1: ...Series BLG TC with Training Central Operation Manual Extra Large Gas Auto Lift Fryer ...
Page 10: ...Gas Auto Lift Fryer Introduction 8 Safety Labels ...
Page 40: ...Gas Auto Lift Fryer Maintenance 38 Oil Over 250 F Pot Pan No Yes ...
Page 45: ...Gas Auto Lift Fryer Maintenance 43 Oil Over 250 F Pot Pan No Yes ...
Page 53: ...Gas Auto Lift Fryer Maintenance 51 18 Confirm the oil level ...