Gas Auto-Lift Fryer
Maintenance
34
Maintenance
Failure to comply with the maintenance below could result in a serious accident.
Your fryer will need periodic maintenance and servicing. We strongly suggest
that you use only a service company that is authorized by BKI
to do this work.
The BLG appliance is not intended to be cleaned with a water jet.
The restraining device must always be connected when the appliance is in
service. Disconnect for movement, such as servicing or cleaning. Reconnect the
restraint when fryer has been returned to its normal position.
Scheduled Maintenance
Use the following table to help manage scheduled maintenance activities.
FREQUENCY
PERFORMED BY
PART
ACTIVITY
Daily
User
Filter Pad
Replace filter pad. Refer to the
procedure in this manual.
User
Filter system
Filter the shortening using the
procedure in this manual.
Weekly
User
Fryer Pot
Perform the boil-out procedure
in this manual.
Every 6 Months
Authorized BKI
service agent
Connections,
Fittings
Check for leakage while oil is
pumping.
Authorized BKI
service agent
Fryer Pot
Fittings/Connections
Check for leakage around fry
pot top deck and fittings
(heaters, hi-limit, thermostat,
etc.).
Summary of Contents for BLG-TC Series
Page 1: ...Series BLG TC with Training Central Operation Manual Extra Large Gas Auto Lift Fryer ...
Page 10: ...Gas Auto Lift Fryer Introduction 8 Safety Labels ...
Page 40: ...Gas Auto Lift Fryer Maintenance 38 Oil Over 250 F Pot Pan No Yes ...
Page 45: ...Gas Auto Lift Fryer Maintenance 43 Oil Over 250 F Pot Pan No Yes ...
Page 53: ...Gas Auto Lift Fryer Maintenance 51 18 Confirm the oil level ...