CT-600-2
83
No. Description
Param. page
on HMI
Default
value
Default
unit
67 Motor 1, 2, 3 current AI calibration factor A
Comp./Motor 3 -
1, 2, 3
1.0
68 Motor 1, 2, 3 speed AO calibration factor A
Comp./Motor 3 -
1, 2, 3
14.29
69 Motor 1, 2, 3 speed AO calibration factor B
Comp./Motor 3 -
1, 2, 3
0.0
70 Oil system pressure drop high warning
Oil System 1
2.0
bar
71 Oil system pressure drop high alarm
Oil System 1
3.0
bar
72 Main oil filter pressure drop high warning
Oil System 1
1.2
bar
73 Main oil filter pressure drop high alarm
Oil System 1
2.0
bar
74 Booster oil pump pressure difference on
Oil System 1
2.8
bar
75 Booster oil pump pressure difference off
Oil System 1
3.3
bar
76 Enable/disable oil pump
Oil System 1
OFF
77 Oil separator load high warning
Oil System 1
0
m3/h
78 Oil separator load high alarm
Oil System 1
0
m3/h
79 OS.A95 oil filter pressure drop high warning
Oil System 1
1.2
bar
80 Oil temperature high warning
Oil System 2
65
°C
81 Oil temperature high alarm
Oil System 2
70
°C
82 Oil temperature low warning
Oil System 2
40
°C
83 Oil temperature low alarm
Oil System 2
15
°C
84 Oil separator temperature low warning
Oil System 2
15
°C
85 Oil separator temperature low alarm
Oil System 2
5
°C
86 Oil separator temp. heater level on
Oil System 2
20
°C
87 Oil separator temp. heater level off
Oil System 2
40
°C
88 PID regulator type
PID 1
NONE
89 PID setpoint suction pressure 1
PID 1
4.3
bara
90 PID setpoint suction pressure 2
PID 1
4.3
bara
91 PID setpoint cold brine 1
PID 1
7.0
°C
92 PID setpoint cold brine 2
PID 1
7.0
°C
93 PID setpoint discharge pressure 1
PID 1
17.0
bara
94 PID setpoint discharge pressure 2
PID 1
17.0
bara
95 PID setpoint hot water 1
PID 1
45.0
°C
96 PID setpoint hot water 2
PID 1
45.0
°C
97 Min capacity output before start
PID 1
10
%
98 PID KP suction pressure (P)
PID 2 - 1
20.0
%/bar
99 PID TN suction pressure (I)
PID 2 - 1
30
s