8
+380 44 507 02 07
Installation and Commissioning
Installation Guide
Tracking device location must ensure connections of sockets and
avoid potential of accidental damage; it also must eliminate exposure to
direct sunlight, moisture, etc. Recommended location of installation in a
vehicle is the empty space under the dashboard inside a vehicle.
GPS and GSM antennae shall also be located in the empty space
under the dashboard of a vehicle.
Antennae cables must be located and clamped along the entire
length with straps clamped to the clamping sites. Cabling must be done
so as to avoid any damage during the operation, when closing
doors/hatches.
Electrical Connections
Power cable shall be passed through special ports in a vehicle body
from the normal battery location to the location where the tracking
device is to be installed. Power cables shall be connected to respective
battery terminals.
ATTENTION!
When performing welding operations during
repairs of a vehicle, MAKE SURE to disconnect power cable
and periphery cables!
Discrete inputs with active "0" respond to connection of these
inputs to GND (ground). This input is inactive when it is not connected
(input is 'blank').
Discrete inputs with active "1" respond to the voltage of over 8 V
on them (connection of the input to the "+" terminal of vehicle network).
This input is inactive when it is not connected (input is 'blank').
Voltage on the analog input may vary from 0 to 24 VDC.
Discrete output is "open collector" type. Load must be connected
into the open between the discrete output and power supply "+"
terminal. When the output is activated it closes to the GND. Max. load
current of the discrete output should not exceed 0.5 А! If high-amperage
currents need to be switched, the discrete outputs must be connected
using additional relay.
ATTENTION!
Voltage on the discrete inputs and outputs
should not exceed 30 V.
Voltage on the analog inputs should not exceed 30 V.
Device input voltage should not exceed 36 V.
Otherwise, the device can be damaged.