18
+380 44 507 02 07
Table 5. List of Parameters for I/O Components
Parameter
No.
Description
Possible values
0
Enabling / disabling
an I/O component
0 – disabled; 1 - enabled
1
Priority of an I/O
component during
sending
0 – low; 1 - high
2
Upper threshold
(depends on I/O component
type)
3
Lower threshold
(depends on I/O component
type)
4
Setting the type of
trigger event
0 – going within range;
1 – going beyond range;
2 – going back within/beyond
range;
3 – monitoring;
4 – moni going within
range;
5 – moni going beyond
range;
6 – moni going
within/beyond range;
7 – event generation by change
of an input by a preset value;
8 – event generation by change
of an input by a preset value +
monitoring.
5
Averaging constant 0+
Clarifications to Table 5:
Parameter 0 – enabling / disabling I/O component transmission to the
server.
Parameter 1 - Priority: low/high. When selecting the "Priority: low"
option, the data from the sensor will be sent to the server with the next
data packet. When selecting the "Priority: high" option, the data will be
sent to the server whenever possible;
Parameter 2 - Upper threshold – setting the upper threshold of the I/O
component;
Parameter 3 - Lower threshold – setting the lower threshold of the I/O
component;