+380 44 507 02 07
Specify the list of enabled carriers:
setparam 0020 <MNC Code>;
setparam 0021 <MNC Code>;
…
setparam 0099 <MNC Code>;
APN, GPRS login, GPRS password need to be configured for each enabled
network individually. The following parameters are used for that matter:
No.
Parameter
name
ID for
configurati
on
Capacity
Parameter purpose
1
UsAPNTable 0060...0099
string
List of APNs of enabled
carriers
2
UsLoginTable 0100...0139
string
List of GPRS logins of
enabled carriers
3
UsPassTable 0140...0179
string
List of GPRS passwords of
enabled carriers
Specify APNs of enabled networks:
setparam 0060 <APN>;
setparam 0061 <APN>;
…
setparam 0099 <APN>;
Specify GPRS logins of enabled networks:
setparam 0100 <GPRS login>;
setparam 0101 <GPRS login>;
…
setparam 0139 <GPRS login>;
Specify GPRS passwords of enabled networks:
setparam 0140 <GPRS password>;
setparam 0141 <GPRS password>;
…
setparam 0179 <GPRS password>;
ATTENTION!
If you specify the list of enabled operators,
but do not specify APN, GPRS login, GPRS password for
each of them, the device will not work in roaming.
Configuring the Device for Operation with RFID Readers
The BI-810 TREK Tracking Device is compatible with RFID readers
via the RS-485 bus.
To configure the reader correctly, please, read its manual carefully
first. To transfer the number of a card read to a server, respective I/O
component needs to be configured.
Apart from transfer of the card number, there is also a feature for
control of discrete output Out 1 depending on the cards being read. For