29
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
Parameter
name
ID for
configu
ration
ID
for
trans
missi
on
Bit
depth
Parameter purpose
Units
Possible values
Default
values
Delta Y
0282
none
1 byte
Acceleration meter Y-
direction deviation angle
c.u.
1 - 256
5
Delta Z
0283
none
1 byte
Acceleration meter Z-
direction deviation angle
c.u.
1 - 256
5
Start Move
Timeout
0284
none
2 byte
Timeout for movement
start by acceleration
meter
0.1
sec.
0 - 65535
50
Stop Move
Timeout
0285
none
2 byte
Timeout for movement
stop by acceleration meter 0.1 sec.
0 - 65535
200
Axel Sleep
Enable
0911
none
1 byte
Enabling sleep by
acceleration meter
none
0 - disabled; 1 -
enabled;
0
Wait Sleep
TM
4007
none
2 byte
Timeout for sleep by
acceleration meter
minutes
5 - 65535
15
Sleep TM
4008
none
2 byte
Sleep timeout by
acceleration meter
minutes
0 - 65535
720
Min GPS
speed
0918
none
1 byte
Minimum speed according
to GPS for movement
detection
km/h
1 - 256
5
GPS Source
Select
4016
none
1 byte
Selecting geopositioning
system
c.u.
0 or 3 -
GPS+GLONASS;
1 - GPS only;
2 - GLONASS
only;
3