35
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
Parameter
name
ID for
configu
ration
ID
for
trans
missi
on
Bit
depth
Parameter purpose
Units
Possible values
Default
values
FactorQ
0951
none
4 byte
Q factor for Kalman filter
c.u.
-
1000000
FactorH
0952
none
4 byte
H factor for Kalman filter
c.u.
-
1000000
FactorRs
0953
none
4 byte
R factor for Kalman filter
with no movement
c.u.
-
20000000
FactorRm
0954
none
4 byte
R factor for Kalman filter
with movement
c.u.
-
400000000
switchFilters
0209
none
1 byte
Switching between filter
types for filtered fuel
meters
none
1 - Kalman filter;
1
Ekey_num
0920…
0939
none
8 byte
ID of enabled electronic
keys
none
-
-
GSM_Reg
Timeout
4019
none
2 byte
Timeout for registration on
the GSM network
sec
60 – 300
120
GPRS_Reg
Timeout
4020
none
2 byte
Timeout for registration on
the GPRS network
sec
60 - 300
120