21
+380 44 507 02 07
transmitted to the server in the monitoring mode.
6 - Moni Going Within/Beyond Range.
When one of the events is generated, actual value from the
sensor starts to be transmitted to the server.
7 - Change of Input by a Preset Value.
When an input value changes increasingly or decreasingly by a
preset value, respective event will be generated. Value of the
setting is specified by the
Upper Threshold
parameter.
8 - Moni Change of Input by a Preset Value.
When the events is generated, actual value from the sensor
starts to be transmitted to the server.
Parameter 5 – Averaging Constant.
It is the time during which an I/O component must be within a particular
state in order to generate an event. This setting is specified in
milliseconds (X*50 msec, i.e. when setting the value to 10, the constant
will be 10*50=500 msec).
The list of all I/O components of the device available for
configuration is given in
Addendum 2
.
Configuring Alarms
The device can be configured so as to make an outbound call if a
particular condition is met. Activation of a particular I/O component
constitutes such condition. Voice calls must be enabled in general
configuration settings of the device. I/O component must be enabled,
configured to one of the events (going within range, going beyond range,
going within/beyond range), its ID must be set as a trigger for outbound
calls, and an authorized phone number Phone0 must be configured.
Note
Outbound call can only be made or an SMS message can only be
sent to a phone number specified in parameter 0261 (Phone0).
Additional prerequisites include device being within the GSM carrier
coverage area and sufficient balance. In case the device is beyond the
coverage area, the call will be postponed until such time when the device
returns back to the coverage area. The device takes one attempt to make
an outbound call per each trigger activation.
Alarm configuration settings are specified in the
Security
section of
Addendum 1
. Authorized phone number Phone0 is specified as the ID
0261 parameter.
Apart from the voice call, the device can send SMS messages to an
authorized phone number, when events are triggered. The IDs of an I/O
components by which SMS messages are sent should be configured as a
trigger for outbound SMS messages. A user-defined text may be included
with an SMS message, but it should not be more than 30 Latin