Parameter 4 – Setting the type of trigger event generated:
0 - Going back within range.
If a certain range is configured for the values of a sensor
(sensor value ranges are set as follows: the lower range
threshold is recorded to a respective parameter –
Lower
Threshold
, the upper threshold is recorded to the
Upper
Threshold
parameter respectively), then the event will be
generated, when actual value of the sensor readings comes
within such configured range. In all other cases the event will
not be generated and no information will be sent to the server.
Example:
Lower threshold of input voltage is set to 0 V, the
upper threshold is 10 V (10000 mV). If the input voltage
decreases lower than 10 V, the event will be generated (Figure
4).
Fig. 4. Generation of the Event by Going Within Range.
1 - Going beyond range.
An event will be generated, when actual value of sensor
readings goes beyond a configured range.
Example:
Lower threshold of input voltage is set to 0 V, the
upper threshold is 10 V (10000 mV). If the input voltage
increases over 10 V, the event will be generated (Figure 5).