Sensor Set-up
Section 1
22
STEP 6
- Test and Commissioning
1.6.3
Remote Self-Test Check
Check that the values in the Remote Self-Test & Monitoring Message from the
previous Data Link check are within the ranges indicated below, in Table 1-5 Remote
maintenance check fields.
Field 1: Space
Message starts with a space
Field 2: 100 or 108
Heater state and error flags
Field 3: 2.450 - 2.550 Internal Reference voltage
Field 4: 9.00 - 36.00
Supply Voltage
Field 5: 10.8 -13.2
Internal operating voltage
Field 6: 4.5 - 5.5
Internal operating voltage
Field 7: 10.8 -13.2
Internal operating voltage
Field 8: 00.00
Not applicable in this check
Field 9: 00.00
Not applicable in this check
Field 10: 85 - 105
Transmitter power monitor
Field 11: 80 - 120
Forward Receiver monitor
Field 12: 80 - 120
Back Receiver monitor
Field 13: 00 - 99
Transmitter Window Contamination
Field 14: 00 - 99
Not applicable in this check
Field 15: 00 - 99
Not applicable in this check
Field 16:
Temperature
o
C
Field 17 3300-4200
ADC Interrupts per second
Table 1-5 Remote maintenance check fields