16. Troubleshooting
Fault description
Possible cause
Required measures
Heating
Unit door not properly closed.
Completely close unit door.
Door gasket defective.
Replace door gasket,
Set-point temperature is not
reached after specified time.
LED (3a) (loss of technical venti-
lation) not lit.
Controller not adjusted.
Calibrate and adjust controller.
Controller defective.
Pt 100 sensor defective.
Semiconductor relay defective
Contact BINDER service.
Chamber heating permanently,
set-point not maintained.
Controller not adjusted.
Calibrate and adjust controller.
Safety device has turned off
the oven.
Limit temperature reached.
Safety device class 2 (chap.
12.1) set too low.
Allow the oven to cool down the
oven and press the “RESET” button.
Check temperature set-point and
setting of safety device (chap. 12.1).
If appropriate, select suitable limit
value.
Semiconductor relay defective.
Controller defective.
Chamber doesn’t heat up.
LED (3a) (loss of technical venti-
lation) not lit.
LED (2a) of safety device lit.
Controller display off.
Fan turning.
Safety device defective.
Contact BINDER service.
Check connection to power supply.
No power supply.
Check if the main power switch (1)
is turned on.
Unit without any function.
Controller defective.
Contact BINDER service.
Deviations from the indicated
heating-up times.
Oven fully loaded.
Charge the oven less or consider
longer heating-up times.
Chamber just turned on, nec-
essary fan speed not yet
reached.
Wait a few minutes.
Fan defective.
Contact BINDER service.
Exhaust air channel blocked.
Flap of exhaust air channel
defective.
Check exhaust air system (customer
side).
Chamber doesn’t heat up.
LED (3a) (loss of technical venti-
lation) lit.
Intake opening blocked
(soiled filter).
Change filter.