NOZ2 M
ANUAL
I
NSTALLATION
Manual version 6.0 - North America (10-03-2017)
en-43
en
For models with
b-control
continuously variable con-
troller
1. If so desired, adjust the output voltage of the controller:
1. Remove the adjustment button.
2. Remove the hexagonal nut.
3. Remove the shut-off cap.
4. Attach a multimeter to ‘Vout’.
5. Set the switch to the minimum voltage:
- Turn the switch all the way to the left;
- Turn it to the right until the switch clicks;
- Carefully turn it to the left until you feel resistance, but
the switch does not quite click.
- Set the desired minimum voltage, using a screwdriver.
Note:
n
Set the minimum voltage to at least 2V.
6. Turn the switch all the way to the right.
7. Set the desired maximum voltage, using a screwdriver.
Note:
n
The set max. voltage must be greater than the set
min. voltage.
8. Fit the shut-off cap.
9. Fasten the hexagonal nut.
10. Fit the adjustment button: Press this on firmly and set
to position ‘0’.
2. Turn the unit on, using the controller.