INSTALLATION MANUAL
Logic
Definition
Default
Cross
out
setting
used
Optional extras
EXPO2
Configura-
tion of EXPO2
output
on input-output
expansion
board
6-7
11
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
12
Output configured as anti-tampering
13
Output configured as Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
TRAFFIC LIGHT
PREFLASHING
Traffic light
pre-flashing
0
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red
light
0
0
Red lights off when gate closed.
1
Red lights on when gate closed.
*
Only active on FW > 1.05 - 2.05 - 3,05
**
Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
Radio channel control configuration
CH logic= 0 - Control configured as Start E. Operation according to
STEP-BY-STEP MOV
. logic. External start for traffic light control.
CH logic= 1 - Control configured as Start I. Operation according to
STEP-BY-STEP MOV
. logic. Internal start for traffic light control.
CH logic= 2 - Control configured as Open.
The command causes the leaves to open.
CH logic= 3 - Control configured as Closed.
The command causes the leaves to close.
CH logic= 4 - Control configured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to
STEP-BY-STEP
. logic
Logica CH= 5- Control configured as STOP.
The command performs a STOP
CH logic= 6 - Control configured as AUX0. (**)
The control activates the AUX0 output
CH logic= 7 - Not used
CH logic= 8 - Not used
CH logic= 9 - Control configured as AUX3. (**)
The control activates the AUX3 output
CH logic= 10 - Control configured as EXPO1. (**)
The control activates the EXPO1 output
CH logic= 11 - Control configured as EXPO2. (**)
The control activates the EXPO2 output
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
TABLE “C” – RADIO MENU (
RADIO
)
Logic
Description
add 1ch
Add 1ch Key
associates the desired key with the 1nd radio channel command.
add 2ch
Add 2ch Key
associates the desired key with the 2nd radio channel command.
add 3ch
Add 3ch Key
associates the desired key with the 3nd radio channel command.
add 4ch
Add 4ch Key
associates the desired key with the 4nd radio channel command.
erase 64
Erase List
WARNING!
Erases all memorized transmitters from the receiver’s memory.
erase 1
Eliminates individual radio control
Removes a radio control (if clone or replay is disabled) To select the radio control to be deleted, enter the position or press a button on the radio
control to be deleted (the position is displayed)
Read receiver code
Displays receiver code required for cloning transmitters.
D812960 00100_04