INSTALLATION MANUAL
ACCESS MENUS Fig. 2
stat
password
- +
- +
OK
vers
bft . . .
+
/
-
OK
0000
+
/
-
+
/
-
n. cycles
OK
OK
01.33
0---
10--
150-
1520
prg
00
- +
err
autoset
02.01
........
30.15
+
/
-
Exit Menù
Confirm/Switch on display
Scroll up
Scroll down
See PARAMETERS MENU
See LOGIC MENU
language
n. remotes
List of last 30 errors
Control unit
software version
No total manoeuvres(in hundreds)
No radio controldevices memorised
ALT
follow the user guide
x2
0---
10--
150-
1520
ok
***
See RADIO MENU
hidden butt
release
desired button
Add. 2ch
hidden butt
release
desired button
hidden butt
release
desired button
Add. 4ch
hidden butt
release
desired button
Add. 1ch
Add. 3ch
erase 64
If cancelled
If not present
If clone, it is disabled
(
0001
)
ok
KO
dis
erase 1
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
(
0000
)
l.sw adj
closing
ONLY FOR PHEBE ULTRA
(
0000
)
opening m1
swc position
opening m2
Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT
PHOT photocell input activated
PHOP
PHOT OP opening photocell input activated
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
baro
Activation of BAR safety edge input with ACTIVE
reversal ONLY WHILE OPENING, or, if configured
as verified safety edge active only while open-
ing, Activation of the associated FAULT input
barc
Activation of BAR safety edge input with ACTIVE
reversal ONLY WHILE CLOSING, or, if configured
as verified safety edge active only while clos-
ing, Activation of the associated FAULT input
SWC
SWC motor closing limit switch input
activated
SWO
SWO motor opening limit switch input
activated
SWO2
SWO2 motor 2 opening limit switch input
activated
SET
The board is standing by to perform a
complete opening-closing cycle uninter-
rupted by intermediate stops in order to
acquire the torque required for movement.
WARNING! Obstacle detection not active
ER01
Photocell test failed
Check photocell connection and/or
logic settings
ER02
Safety edge test failed
Check safety edge connection and/
or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or
parameter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or
parameter/logic setting
er06
8k2 safety edge test failed
Check safety edge connection and/or
parameter/logic settings
ER1x
*
Board hardware test error
- Check connections to motor
- Hardware problems with board
(contact technical assistance)
ER2x
*
Encoder error
- Motor power or encoder signal cables
inverted/disconnected.
- Actuator movement is too slow or
stopped with respect to programmed
operation.
ER3x
*
Reverse due to obstacle - Amperostop
Check for obstacles in path
ER4x
*
Thermal cutout
Allow automated device to cool
ER70
ER71
ER74,
ER75
Internal system supervision control error.
Try switching the board off and back
on again. If the problem persists,
contact the technical assistance
department.
ER72
Consistency error of the control unit’s parame-
ters (Logics and Parameters)
Pressing OK the detected settings are
confirmed. The board will keep on
working with the detected settings.
The board settings must be
checked
(Parameters and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on
working with D-track as a default.
An autoset is required
ERf0
Limit switch error
check limit switch connections
erf1
Limit switch error always active after ope-
ration start
Check limit switch and motor con-
nections
erf9
Solenoid lock output overload
-Check lock connections
- Unsuitable lock
*
X
= 0,1,…,9,A,B,C,D,E,F