INSTALLATION MANUAL
ENGLISH
TABLE “B” - LOGIC MENU - (
logic
)
Logic
Definition
Default
Cross
out
setting
used
Optional extras
MOTOR TYPE
(only for VEGA
CPEL)
Motor type
(Set the type of
motor connected
to the board).
0
0
PHEBE BT A U
1
PHEBE ULTRA BT A
TCA
Automatic
Closing Time
0
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
MOVEMNT
Step-by-step
movement
0
0
Inputs configured as Start E, Start I, Ped
operate with 4-step logic.
step-by-step mov.
2 STEP
3 STEP
4 STEP
CLOSED
OPENS
OPENS
OPENS
DURING
CLOSING
STOPS
OPEN
CLOSES
CLOSES
CLOSES
DURING
OPENING
STOP + TCA STOP + TCA
AFTER STOP
OPENS
OPENS
OPENS
1
Inputs configured as Start E, Start I, Ped op-
erate with 3-step logic. Pulse during closing
reverses movement.
2
Inputs configured as Start E, Start I, Ped op-
erate with 2-step logic. Movement reverses
with each pulse.
PRE-ALARM
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
IBL OPEN
Block pulses
during opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
|IBL TCA
Block pulses
during TCA
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
IBL CLOSE
Block pulses
during closing
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
RAM BLOW C.OP
Hammer during
opening
0
0
Logic not enabled
1
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid lock to
be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
PRESS SWC
Closing limit
switch pressure
1
0
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit
switch must be adjusted accurately.
1
This function allows leaves to press against the mechanical stop without this being considered as an obstacle.
After intercepting the closing limit switch, the motor continues to be supplied for 3s longer.
ICE
Ice feature
0
0
The Amperostop safety trip threshold stays at the same set value.
1
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the
value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
1 MOT.ON
1 motor active
1
0
Checks the second motor (connected to terminals 14 and 15) independently from the first motor. The opening
limit switch needs to be connected to the second motor (PHEBE ULTRA BT A SQ terminals 70-16). See Fig. E ref. 2-3.
1
The second motor (if any) (connected to terminals 14 and 15) is in parallel with the main motor. The opening limit
switch does not need to be connected to the second motor (PHEBE ULTRA BT A SQ terminals 70-16). See Fig.H Ref. 2-3.
OPEN IN
OTHER DIRECT
(only for VEGA)
Open in other
direction
0
0
Standard operating mode.
1
Opens in other direction to standard operating mode.
ATTENTION: with the Opening direction reversal logic active, the active motor 1 logic is activated
automatically.
SAFE 1
Configuration
of safety input
SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
9*
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
10*
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
movement stops.
11*
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the move-
ment stops.
12*
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
13*
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
movement stops.
14*
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the move-
ment stops.
D812960 00100_04
VEGA - VEGA ULTRA
- 39